<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Internal Medicine Today</title>
<title_fa>طب داخلی روز</title_fa>
<short_title>Intern Med Today</short_title>
<subject>Medical Sciences</subject>
<web_url>http://imtj.gmu.ac.ir</web_url>
<journal_hbi_system_id>80</journal_hbi_system_id>
<journal_hbi_system_user>journal80</journal_hbi_system_user>
<journal_id_issn>2981-0086</journal_id_issn>
<journal_id_issn_online>2981-0086</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.18869/acadpub.hms</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1398</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2020</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بهبود کنتراست نسبی در سکانس تصویربرداری سه‌بعدی DESS به منظور تشخیص بهتر ناهنجاری‌های غضروفی زانو</title_fa>
	<title>Comparing Relative Contrast in Three-dimensional Double-echo Steady State With Routine Sequences for a Better Diagnosis of Knee Cartilage Anomalies</title>
	<subject_fa>علوم پايه پزشكي</subject_fa>
	<subject>Basic Medical Science</subject>
	<content_type_fa>پژوهشی</content_type_fa>
	<content_type>Original</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;اهداف &lt;/strong&gt;هدف از این مطالعه، مقایسه مقادیر کنتراست نسبی در سکانس&#8204;های سه&#8204;بعدی DESS با دو زاویه فلیپ ۴۰ و ۹۰ درجه با سایر سکانس&#8204;های روتین به منظور اثبات کارآمدی این سکانس در مقایسه با سایر سکانس&#8204;های رایج نظیر سکانس PD ،T2 ،STIR و سکانس سه&#8204;بُعدی FLASH در مشاهده بهتر ضایعات حاصل از ناهنجاری&#8204;های غضروفی در تصویربرداری تشدید مغناطیسی است.&lt;br&gt;
&lt;strong&gt;مواد و روش ها&lt;/strong&gt; ۱۵ بیمار که شامل ۹ آقا (۱۴-۵۶ سال) و شش خانم (۳۶-۶۵ سال) که دارای علائم زانو&#8204;درد بودند با معرفی پزشک ارتوپد تحت تصویربرداری تشدید مغناطیسی (MRI) با استفاده از سکانس&#8204;های سه&#8204;بُعدی DESS با دو زاویه فلیپ ۹۰ و ۴۰ با سکانس&#8204;های PD T2 ،STIR و سکانس سه&#8204;بُعدی FLASH قرار گرفتند و تصاویر حاصل با استفاده از نرم&#8204;افزار Radiant DICOM Viewer 4.6.9 مورد آنالیز قرار گرفت و مقادیر کنتراست نسبی برای تصاویر ساژیتال انتخاب&#8204;شده در هر سکانس برای هر بیمار به دست آمد. آنالیز آماری داده&#8204;های به&#8204;دست&#8204;آمده با استفاده از نسخه 16 نرم&#8204;افزار آماری SPSS انجام شد.&amp;nbsp;&lt;br&gt;
&lt;strong&gt;یافته ها&lt;/strong&gt; تست&#8204;های آماری فریدمن و ویلکاکسون مقادیر معنادار P (کمتر از ۰/۰۵) را بین تمام سکانس&#8204;های مورد&#8204;بررسی در این مطالعه نشان دادند. سکانس DESS با زاویه فلیپ ۹۰ درجه با داشتن میانگین مقدار کنتراست نسبی 77/2667 دارای بهترین مقدار بود و در این بین سکانس FLASH با داشتن مقدار ۳/۷۳۳ دارای کمترین مقدارمیانگین کنتراست نسبی بود.&amp;nbsp;&lt;br&gt;
&lt;strong&gt;نتیجه گیری&lt;/strong&gt; سکانس DESS با زاویه فلیپ ۹۰ درجه دارای بهترین مقادیر کنتراست نسبی بود و بهترین سیگنال ممکن را از محل مایع مفصلی و نیز محل غضروف در تصویر فراهم کرد و بدین ترتیب امکان بررسی هرچه بهتر غضروف مفصلی را از نظر داشتن ضایعه مهیا می&#8204;کند؛ بنابراین سکانس DESS با زاویه فلیپ ۹۰ درجه بهترین سکانس برای بررسی ناهنجاری&#8204;های غضروفی در بین سکانس&#8204;های مورد بررسی این مطالعه است.&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;Aims This study compared relative contrast values in three-dimensional Double Echo Steady State (DESS) sequences with two flip angles of 40 and 90 degrees and other routine sequences. The obtained data could help to prove the effects of this sequence, compared to the other routine sequences; accordingly, it could be applied for better detection of lesions resulting from cartilage abnormalities.&lt;br&gt;
Methods &amp; Materials Total, 15 patients, including 9 men (14-56 y) and 6 women (36-65 y) with knee pain symptoms were referred to us by an orthopedic physician. All of the investigated patients underwent Magnetic Resonance Imaging (MRI) using DESS sequences with two flip angles of 40 and 90 degrees, as well as STIR , PD, T2, and 3D FLASH. We analyzed the acquired images using the Radiant DICOM Viewer4.6.9 software. We calculated relative contrast values for the selected SAGITAL images per sequence for each patient. The obtained data were analyzed using SPSS.&lt;br&gt;
Findings Friedman and Wilcoxon statistical tests data revealed significant P values (&lt;0.05) for all the sequences examined in this study. The DESS sequence with a flip angle of 90&amp;deg; presented the most relative contrast value with the average score of 77.2667. The FLASH sequence provided the worst result of 3.733 for the relative contrast value.&lt;br&gt;
Conclusion The DESS sequence with 90&amp;deg; flip angle indicated the best relative contrast values and provided the best possible signal from the synovial fluid and the cartilage; therefore, it leads to the better examination of articular cartilage in terms of lesion. Accordingly, the DESS sequence with a flip angle of 90&amp;deg; was the optimal sequence to evaluate cartilage abnormalities among the examined sequences in this study.&lt;/div&gt;</abstract>
	<keyword_fa>تصویربرداری تشدید مغناطیسی(MRI), استئوآرتریت ,پروتکل DESS ,PD,STIR</keyword_fa>
	<keyword>MRI, Osteoarthritis, DESS protocol, STIR, PD</keyword>
	<start_page>108</start_page>
	<end_page>117</end_page>
	<web_url>http://imtj.gmu.ac.ir/browse.php?a_code=A-10-2008-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Sepehr</first_name>
	<middle_name></middle_name>
	<last_name>Lotfi Marangaloo</last_name>
	<suffix></suffix>
	<first_name_fa>سپهر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>لطفی مرنگلو</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>seplotfi@gmail.com</email>
	<code>8000319475328460032232</code>
	<orcid>8000319475328460032232</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.</affiliation>
	<affiliation_fa>مرکز تحقیقات فیزیک پزشکی، دانشگاه علوم‌پزشکی مشهد، مشهد، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Amir Shahriar</first_name>
	<middle_name></middle_name>
	<last_name>Ariamanesh</last_name>
	<suffix></suffix>
	<first_name_fa>امیرشهریار</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آریامنش</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>drariamanesh@yahoo.com</email>
	<code>8000319475328460032233</code>
	<orcid>8000319475328460032233</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Orthopedics, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.</affiliation>
	<affiliation_fa>بخش ارتوپدی، گروه بالینی، دانشکده پزشکی، دانشگاه علوم‌پزشکی مشهد، مشهد، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Behzad</first_name>
	<middle_name></middle_name>
	<last_name>Aminzadeh</last_name>
	<suffix></suffix>
	<first_name_fa>بهزاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امین زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>aminzadehb@mums.ac.ir</email>
	<code>8000319475328460032234</code>
	<orcid>8000319475328460032234</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Radiology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.</affiliation>
	<affiliation_fa>گروه رادیولوژی، دانشکده پزشکی، دانشگاه علوم‌پزشکی مشهد، مشهد، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Hormoz</first_name>
	<middle_name></middle_name>
	<last_name>Abedi</last_name>
	<suffix></suffix>
	<first_name_fa>هرمز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عابدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>habedimp@gmail.com</email>
	<code>8000319475328460032235</code>
	<orcid>8000319475328460032235</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.</affiliation>
	<affiliation_fa>مرکز تحقیقات فیزیک پزشکی، دانشگاه علوم‌پزشکی مشهد، مشهد، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Alireza</first_name>
	<middle_name></middle_name>
	<last_name>Montazerabadi</last_name>
	<suffix></suffix>
	<first_name_fa>علیرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>منتظرابدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>alireza.montazerabadi@gmail.com</email>
	<code>8000319475328460032236</code>
	<orcid>8000319475328460032236</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.</affiliation>
	<affiliation_fa>مرکز تحقیقات فیزیک پزشکی، دانشگاه علوم‌پزشکی مشهد، مشهد، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
