kheradpisheh Z, Movahedian Attar H, Salehi M. Comparision of Removal Efficiency of Cyanide by Chemical and Electrochemical Precipitation Process from Industrial Wastewater. Intern Med Today 2012; 18 (2) :71-77
URL:
http://imtj.gmu.ac.ir/article-1-996-en.html
1- , z.kheradpisheh@yahoo.com
Abstract: (9345 Views)
Background and Aim: Cyanide is a highly toxic compound which is found normally in the wastewater
of numerous industries, such as Electroplating. The release of this compound into the environment has a
lot of health hazards. The Purpose of this study was to compare the electrochemical oxidation efficiency
with chemical precipitation method for cyanide removal from industrial wastewater.
Materials and Methods: This study was conducted experimentally in a pilot system. In this study, the
optimum conditions such as pH , Fe/CN- and reaction time were investigated in the Ferrous Sulfate
precipitation method for cyanide removal from wastewater of electroplating industries by the use of jar
test. It also investigated the effect of pH, voltage and operation time for total cyanide removal by
electrochemical oxidation method by applying a stainless steel as an anode and copper as a cathode. And
finally, the efficiency of two methods was compared.
Results: In the Ferrous Sulfate Precipitation method, the optimal conditions were obtained for the
removal of cyanide at (pH 6/5, and 10:1 Molar Ratio and Operation Time 60 minutes). In these
conditions, the removal efficiency was 93 percent. In the electrochemical method, the optimal conditions
were obtained at the voltage of 9V and pH=13 and the operation time of 90 minutes in which the average
percentage removal of cyanide was about 88 with SD=2.43. The results statistically confirmed the
significant relationship between cyanide removal efficiency and optimal conditions in both methods (p<
0.05). But comparison of the two methods showed that the cyanide removal efficiency in the
electrochemical method was as much as the chemical precipitation method.
Conclusion: Due to the high cyanide removal efficiency and achieving the standards for effluent disposal
to the environment, it seems that ferrous Sulfate precipitation method is more useful.
Type of Study:
Original |
Subject:
Laboratory Medicine Received: 2011/01/11 | Accepted: 2012/07/11 | Published: 2012/07/15